Frostline.info

Frost line depth in Bureau County, Illinois

Frost reaches about 40 inches in typical soil across Bureau County. Codes in this climate commonly set footing depth at 36 to 48 inches.

Deep frost
Estimated frost depth
40″
typical silt/loam soil
Typical code footing depth
36–48″
rule of thumb for this climate
Design freezing index
1,637
°F-days, 100-year winter
ZIP codes covered
15
#15 of 102 counties in IL (1 = deepest)
40″ 0″12″24″36″48″60″72″ ground frozen
Est. frost (typical soil) Typical code footing depth Clay–sand range

Frost depth by soil type

Soil typeEst. frost depth
Sand / gravel (drains well)50″
Silt / loam (typical yard soil)40″
Clay (holds water)34″

County average. Methodology.

Verify before you dig. These are climate-based estimates. The legally required frost depth is the figure your building department publishes in its IRC Table R301.2 (climatic and geographic design criteria). Call the Bureau County building or permitting office in Illinois and call 811 before digging.

Frost depth by ZIP code in Bureau County

ZIPCityEst. frostCode range
61312Arlington39″30–48″
61314Buda41″36–54″
61320Dalzell39″30–48″
61329Ladd39″30–48″
61330La Moille40″36–48″
61337Malden39″36–48″
61344Mineral41″36–54″
61345Neponset41″36–54″
61349Ohio40″36–54″
61356Princeton40″36–48″
61361Sheffield41″36–54″
61362Spring Valley39″30–48″
61368Tiskilwa40″36–48″
61376Walnut40″36–54″
61379Wyanet40″36–48″

What this means for your project in Bureau County

Deck footings & piers

Footings must bear below the frost line and at least 12″ below undisturbed ground. For planning in this area, budget for holes around 48″ deep until your permit office confirms the exact figure.

Fence posts

Set posts at least one-third of their above-ground height. Where frost heave is a problem, carry concrete footings below the frost line (about 40″ here in typical soil) and bell or taper the bottom.

Water & irrigation lines

Bury supply lines below the frost depth. Your water utility or plumbing code sets the minimum cover; in a climate this cold, 4 feet or more is common for service lines.

Slabs & frost-protected foundations

Frost-protected shallow foundations (IRC R403.3) use the 100-year air freezing index — 1,637 °F-days here — to size perimeter insulation, letting footings sit shallower than the frost line.

Weather stations used

NOAA weather stationDistance100-yr AFI
Walnut, IL13 mi1,686
Peru 2 W, IL17 mi1,552
Kewanee, IL25 mi1,693
Dixon, IL30 mi1,792

Nearby counties

Common questions

What is the frost line depth in Bureau County?

About 40 inches in typical soil, based on NOAA's 100-year air freezing index. Across the county's ZIP codes the estimate runs from 39 to 41 inches.

How deep should footings be in Bureau County, Illinois?

Codes in climates like this commonly require 36 to 48 inches. The Bureau County building department publishes the required frost depth in its adopted code (IRC Table R301.2).

Does frost depth vary within Bureau County?

Very little. Estimates across the county stay within 2 inches. Soil type matters more than location here.