Frostline.info

Frost line depth in St. Landry Parish, Louisiana

Frost reaches about 5 inches in typical soil across St. Landry Parish. Codes in this climate commonly set footing depth at 12 to 18 inches.

Shallow frost
Estimated frost depth
5″
typical silt/loam soil
Typical code footing depth
12–18″
rule of thumb for this climate
Design freezing index
26
°F-days, 100-year winter
ZIP codes covered
10
#40 of 64 counties in LA (1 = deepest)
5″ 0″12″24″36″ ground frozen
Est. frost (typical soil) Typical code footing depth Clay–sand range

Frost depth by soil type

Soil typeEst. frost depth
Sand / gravel (drains well)6″
Silt / loam (typical yard soil)5″
Clay (holds water)4″

County average. Methodology.

Verify before you dig. These are climate-based estimates. The legally required frost depth is the figure your building department publishes in its IRC Table R301.2 (climatic and geographic design criteria). Call the St. Landry Parish building or permitting office in Louisiana and call 811 before digging.

Frost depth by ZIP code in St. Landry Parish

ZIPCityEst. frostCode range
70512Arnaudville5″12–18″
70535Eunice5″12–18″
70570Opelousas5″12–18″
70577Port Barre5″12–18″
70584Sunset5″12–18″
70589Washington5″12–18″
70750Krotz Springs5″12–18″
71353Melville5″12–18″
71356Morrow6″12–18″
71358Palmetto5″12–18″

What this means for your project in St. Landry Parish

Deck footings & piers

Footings must bear below the frost line and at least 12″ below undisturbed ground. For planning in this area, budget for holes around 18″ deep until your permit office confirms the exact figure.

Fence posts

Set posts at least one-third of their above-ground height. Where frost heave is a problem, carry concrete footings below the frost line (about 12″ here in typical soil) and bell or taper the bottom.

Water & irrigation lines

Bury supply lines below the frost depth. Your water utility or plumbing code sets the minimum cover; freezing is rare, but exposed pipes still need insulation.

Slabs & frost-protected foundations

Frost-protected shallow foundations (IRC R403.3) use the 100-year air freezing index — 26 °F-days here — to size perimeter insulation, letting footings sit shallower than the frost line.

Weather stations used

NOAA weather stationDistance100-yr AFI
Grand Coteau, LA10 mi22
Melville, LA16 mi29
Lafayette Airport, LA26 mi19
Bunkie, LA28 mi36

Nearby counties

Common questions

What is the frost line depth in St. Landry Parish?

About 5 inches in typical soil, based on NOAA's 100-year air freezing index. Across the county's ZIP codes the estimate runs from 5 to 6 inches.

How deep should footings be in St. Landry Parish, Louisiana?

Codes in climates like this commonly require 12 to 18 inches. The St. Landry Parish building department publishes the required frost depth in its adopted code (IRC Table R301.2).

Does frost depth vary within St. Landry Parish?

Very little. Estimates across the county stay within 1 inches. Soil type matters more than location here.