Frostline.info

Frost line depth in Northumberland County, Pennsylvania

Frost reaches about 31 inches in typical soil across Northumberland County, from 30″ in the mildest ZIP code to 33″ in the coldest. Codes in this climate commonly set footing depth at 24 to 42 inches.

Deep frost
Estimated frost depth
31″
typical silt/loam soil
Typical code footing depth
24–42″
rule of thumb for this climate
Design freezing index
1,013
°F-days, 100-year winter
ZIP codes covered
18
#43 of 68 counties in PA (1 = deepest)
31″ 0″12″24″36″48″60″ ground frozen
Est. frost (typical soil) Typical code footing depth Clay–sand range

Frost depth by soil type

Soil typeEst. frost depth
Sand / gravel (drains well)39″
Silt / loam (typical yard soil)31″
Clay (holds water)27″

County average. Methodology.

Verify before you dig. These are climate-based estimates. The legally required frost depth is the figure your building department publishes in its IRC Table R301.2 (climatic and geographic design criteria). Call the Northumberland County building or permitting office in Pennsylvania and call 811 before digging.

Frost depth by ZIP code in Northumberland County

ZIPCityEst. frostCode range
17017Dalmatia30″24–36″
17772Turbotville31″30–42″
17777Watsontown31″30–42″
17801Sunbury30″24–42″
17823Dornsife30″24–36″
17824Elysburg32″30–42″
17830Herndon30″24–36″
17834Kulpmont32″30–42″
17836Leck Kill31″24–42″
17840Locust Gap33″30–42″
17847Milton31″24–42″
17851Mount Carmel33″30–42″
17857Northumberland30″24–42″
17860Paxinos32″30–42″
17866Coal Township32″30–42″
17867Rebuck31″24–42″
17872Shamokin32″30–42″
17881Trevorton32″30–42″

What this means for your project in Northumberland County

Deck footings & piers

Footings must bear below the frost line and at least 12″ below undisturbed ground. For planning in this area, budget for holes around 42″ deep until your permit office confirms the exact figure.

Fence posts

Set posts at least one-third of their above-ground height. Where frost heave is a problem, carry concrete footings below the frost line (about 31″ here in typical soil) and bell or taper the bottom.

Water & irrigation lines

Bury supply lines below the frost depth. Your water utility or plumbing code sets the minimum cover; in a climate this cold, 4 feet or more is common for service lines.

Slabs & frost-protected foundations

Frost-protected shallow foundations (IRC R403.3) use the 100-year air freezing index — 1,013 °F-days here — to size perimeter insulation, letting footings sit shallower than the frost line.

Weather stations used

NOAA weather stationDistance100-yr AFI
Williamsport, PA32 mi993
Newport, PA34 mi957
Freeland, PA42 mi1,255
Lewistown, PA50 mi855

Nearby counties

Common questions

What is the frost line depth in Northumberland County?

About 31 inches in typical soil, based on NOAA's 100-year air freezing index. Across the county's ZIP codes the estimate runs from 30 to 33 inches.

How deep should footings be in Northumberland County, Pennsylvania?

Codes in climates like this commonly require 24 to 42 inches. The Northumberland County building department publishes the required frost depth in its adopted code (IRC Table R301.2).

Does frost depth vary within Northumberland County?

Very little. Estimates across the county stay within 3 inches. Soil type matters more than location here.