Frostline.info

Frost line depth in Hico, TX 76457

Frost can reach about 9 inches deep in typical soil here (8″ in clay to 11″ in sand). Local codes in climates like this commonly set footing depth at 12 to 18 inches.

Shallow frost
Estimated frost depth
9″
typical silt/loam soil
Typical code footing depth
12–18″
rule of thumb for this climate
Design freezing index
79
°F-days, 100-year winter
Mean annual temp
65.8°F
nearest stations
9″ 0″12″24″36″ ground frozen
Est. frost (typical soil) Typical code footing depth Clay–sand range

Frost depth by soil type

Soil typeEst. frost depth
Sand / gravel (drains well)11″
Silt / loam (typical yard soil)9″
Clay (holds water)8″

Estimates use the modified Stefan equation with a turf / light-snow surface. Bare, plowed or paved ground freezes deeper; deep snow cover keeps frost shallower. How we calculate this.

Verify before you dig. These are climate-based estimates. The legally required frost depth is the figure your building department publishes in its IRC Table R301.2 (climatic and geographic design criteria). Call the Hamilton County building or permitting office in Texas and call 811 before digging.

What this means for your project in Hico

Deck footings & piers

Footings must bear below the frost line and at least 12″ below undisturbed ground. For planning in this area, budget for holes around 18″ deep until your permit office confirms the exact figure.

Fence posts

Set posts at least one-third of their above-ground height. Where frost heave is a problem, carry concrete footings below the frost line (about 12″ here in typical soil) and bell or taper the bottom.

Water & irrigation lines

Bury supply lines below the frost depth. Your water utility or plumbing code sets the minimum cover; freezing is rare, but exposed pipes still need insulation.

Slabs & frost-protected foundations

Frost-protected shallow foundations (IRC R403.3) use the 100-year air freezing index — 79 °F-days here — to size perimeter insulation, letting footings sit shallower than the frost line.

Weather data behind this estimate

NOAA weather stationDistance100-yr AFI
Hico, TX1.7 mi79
Dublin, TX20.5 mi97
Whitney Dam, TX39.3 mi66

76457 ranks #3 of 4 ZIP codes in Hamilton County for frost depth (1 = deepest).

Nearby ZIP codes

All of Hamilton County →

Common questions

How deep is the frost line in Hico, TX?

Based on NOAA's 100-year air freezing index of 79 °F-days for 76457, frost can reach about 9 inches in typical soil, 8 inches in clay and 11 inches in sand or gravel.

How deep do deck footings need to be in 76457?

Footings must sit below the local frost line and at least 12 inches below undisturbed soil. In climates like Hico, codes commonly set the depth at 12 to 18 inches. The Hamilton County building department sets the exact requirement.

Why does soil type change the frost depth?

Wet clay holds a lot of water, and freezing that water releases heat that slows the frost. Dry sand and gravel hold little water and conduct cold faster, so frost goes deeper.

Where does this data come from?

Freezing-index values come from NOAA National Climatic Data Center station records (1951–80), the same data behind the air-freezing-index map in the International Residential Code. We average the three nearest stations, weighted by distance.