Frostline.info

Frost line depth in Prince of Wales-Hyder Census Area, Alaska

Frost reaches about 28 inches in typical soil across Prince of Wales-Hyder Census Area, from 23″ in the mildest ZIP code to 33″ in the coldest. Codes in this climate commonly set footing depth at 24 to 36 inches.

Moderate frost
Estimated frost depth
28″
typical silt/loam soil
Typical code footing depth
24–36″
rule of thumb for this climate
Design freezing index
782
°F-days, 100-year winter
ZIP codes covered
10
#31 of 33 counties in AK (1 = deepest)
28″ 0″12″24″36″48″ ground frozen
Est. frost (typical soil) Typical code footing depth Clay–sand range

Frost depth by soil type

Soil typeEst. frost depth
Sand / gravel (drains well)35″
Silt / loam (typical yard soil)28″
Clay (holds water)24″

County average. Methodology.

Verify before you dig. These are climate-based estimates. The legally required frost depth is the figure your building department publishes in its IRC Table R301.2 (climatic and geographic design criteria). Call the Prince of Wales-Hyder Census Area building or permitting office in Alaska and call 811 before digging.

Frost depth by ZIP code in Prince of Wales-Hyder Census Area

ZIPCityEst. frostCode range
99830Kake31″24–42″
99836Port Alexander26″24–36″
99918Coffman Cove33″30–42″
99919Thorne Bay27″24–36″
99921Craig24″24–30″
99922Hydaburg24″18–30″
99923Hyder25″24–30″
99925Klawock28″24–36″
99926Metlakatla23″18–30″
99927Point Baker32″30–42″

What this means for your project in Prince of Wales-Hyder Census Area

Deck footings & piers

Footings must bear below the frost line and at least 12″ below undisturbed ground. For planning in this area, budget for holes around 36″ deep until your permit office confirms the exact figure.

Fence posts

Set posts at least one-third of their above-ground height. Where frost heave is a problem, carry concrete footings below the frost line (about 28″ here in typical soil) and bell or taper the bottom.

Water & irrigation lines

Bury supply lines below the frost depth. Your water utility or plumbing code sets the minimum cover; add a margin below the estimate above for unusually cold winters.

Slabs & frost-protected foundations

Frost-protected shallow foundations (IRC R403.3) use the 100-year air freezing index — 782 °F-days here — to size perimeter insulation, letting footings sit shallower than the frost line.

Weather stations used

NOAA weather stationDistance100-yr AFI
Wrangell, AK50 mi1,236
Ketchikan, AK59 mi561
Beaver Falls, AK64 mi709
Petersburg, AK69 mi1,417

Nearby counties

Common questions

What is the frost line depth in Prince of Wales-Hyder Census Area?

About 28 inches in typical soil, based on NOAA's 100-year air freezing index. Across the county's ZIP codes the estimate runs from 23 to 33 inches.

How deep should footings be in Prince of Wales-Hyder Census Area, Alaska?

Codes in climates like this commonly require 24 to 36 inches. The Prince of Wales-Hyder Census Area building department publishes the required frost depth in its adopted code (IRC Table R301.2).

Does frost depth vary within Prince of Wales-Hyder Census Area?

Yes. Estimates differ by 10 inches between the coldest and mildest ZIP codes, mostly from latitude and elevation. Check your own ZIP below.